13.4 Ltr ISO9809 2M3 150bar 37MN Oxygen Tanks Gas Cylinders
Information om produktet:
1、13.4-litre medical oxygen cylinder steel cylinder; TUV; 37 mn manganese steel; Oxygen cylinder production standard GB/T5099.3 or ISO9809-3; Cylinder outer diameter is 140mm or 159mm; Oxygen cylinder hydrostatic test pressure is 250bar; Working pressure is 150bar;
2、Oxygen cylinder body height 1069mm or 861mm; Oxygen cylinder body weight 15.5kg or 15.4 kg; Oxygen cylinder mouth thread PZ27.8,25E; 3/4-14 NGT, etc.; Maximum oxygen tank storage capacity is 2m3 (2000 litres); The minimum design wall thickness of oxygen cylinder is 4.3mm;
3、Alias: 13.4 LTR Gas cylinders; 2 m3 Oxygen tanks. LTR Oxygen cylinders; 13.4 LTR Oxygen Tanks; 150bar 37mn gas tanks
4、Heat treatment:Whenever cylinders are reheat treated, the minimum guaranteed wall thickness shall be maintained.
Only the relevant prototype or batch tests needed to prove the acceptability of the batch shall be performed again. If one or more of these retests prove even partially unsatisfactory, all cylinders of the batch shall be rejected.
Shandong Hongsheng Pressure Vessel Co, Ltd. er villig til at være din langsigtede partner og chef for cylindersikkerhed og i fællesskab eskortere din cylindersikkerhed.
1 、 Mindste ordremængde: Kun 100 stk.
2 、 Brug af cylindre: Vores sømløse stålcylindre bruges i vid udstrækning i industrien, medicinsk udstyr, brandbekæmpelse og videnskabelig forskning
3、We are China’s gas cylinder production factory, product sales:China, Southeast Asia, Middle East, Asia, Africa, Europe, Oceania, America
4、Cylinder water pressure testing process:With water as the pressurizing medium, gradually increase the pressure in the test bottle to reach the hydrostatic test pressure of the gas cylinder. Test and verify the safe carrying capacity of gas cylinders. Including measuring its volume deformation rate in the hydrostatic test to determine its safety and reliability, the pressure holding time is 30s.
5、Normalizing heat treatment in which a cylinder is heated to a uniform temperature above the upper critical point, Ac3, of the steel and then cooled in still air
6、For cylinders with hydraulic test pressure ph > 450 bar, the upper cyclic pressure may be reduced to two thirds of this test pressure. In this case, the cylinders shall withstand 80 000 cycles without failure. The value of the lower cyclic pressure shall not exceed 10 % of the upper cyclic pressure, but shall have an absolute maximum of 30 bar.
7、13.4 litre Gas Cylinder Product Parameters table (ISO9809-3)
Type | Udenfor
Diameter (mm) |
Vand
Kapacitet (L) |
Flaske
Højde (mm) |
Vægt
(kg) |
Arbejde
Tryk (Bar) |
Design væg
tykkelse (mm) |
Materiale
Karakterer |
WMAⅡ140-13.4L-150 | 140 | 13.4 | 1069 | 15.5 | 150 | 3.8 | 37MN |
WMAⅡ159-13.4L-150 | 159 | 13.4 | 861 | 15.4 | 150 | 3.9 | 37MN |
WMAⅡ180-13.4L-150 | 180 | 13.4 | 721 | 18.6 | 150 | 4.4 | 37MN |